Dual Output AC Current Transducer (FPAT)

Kind: Two-wire Transmitter
Type: AC Transmitter
Phase: Single
Wire-Assembly Type: Two-wire Transmitter
Accuracy Grade: 0.2G
Certification: ISO
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
FPAT
Customized
Customized
Manufacturers
Haiyan Jinhan Electronic Technology Co., Ltd
MOQ
1 Piece
Production Process
Integration
Shell Material
Iron-Shell
N.W
About 1kg
Freight
by Ari
Delivery Time
1week
Export Markets
Global
Output
Dual Output
Transport Package
Original Packaging
Specification
IEC688-1992
Trademark
jinhan
Origin
China
HS Code
9030390000
Production Capacity
3000 PCS/Year

Product Description

1 Summarize
Electric quantity transducer is a measuring instrument that it makes measurand electric quantity(AC Current/Voltage\Active Power Reactive Power\Active Energy\Reactive Energy\Power Line Frequency Phase Angle\Power Factor\DC Current/Voltage) turn into DC current or voltage output that accroding to proportional linearity. It widely applied to electric measurement\autocontrol and system altitude that in electric power\Coal\metallurgy\railway and so on.

Applied Standards & Rules
Measuring and conversion IEC688/1992-04
Dielectrical strength IEC6882KVac/1min.
Surge and Impulse test ANSIC37.90/1989
IEC 255-3(1989) 4KV 1.2 x 50us

2 Technical Specifications
ReferenceStandard: GB/T 13850-1998 (IEC688-1992)
Accuracy: 0.2%
Long term stability: ≤ 0.2%/year Noaccumulationerror
Temperature influence: ≤ 100ppm/
Response Time: < 400ms
Output Ripple: <4% (peak-peak value)
Input burden: Current less 0.2 VA; Voltageless 0.1 VA
Frequency: Nominalfrequency ± 10%
Maximum output load: Current output Max10V pressure drop
Voltage output rated 2mA MAX 5mAoutput
Auxiliary power: Rated voltage 80%-120%, rated current 90%-110%
Auxiliary load effect: <± 0.1%
Allow excessive input: Current3rate continuous10 rate 30 secs voltage Max 2rate continuous
Dielectric strength: Input /output /power/betwem the crust2KV AC 1min IEC866
Impact test: ANSIC37.90A/1973, IEC 255-4 (5kV 1.2/50us Pulsed Voltage)
Calibration amplitude: Full scale least 3%, zero least 1%
Magnetic field effect: 0.4KA/m magnetic field strength change<0.05%
Operating condition: Temperature -10~55° C relative humidity
≤ 95% RH non condensing
Storage condition: Temperature -40~70° C relative humidity
≤ 95% RH non condensing

3 Models Specifications
FPA-A2-F1-P2-O3 FPV-V1-F1-P2-O3 FPAT-A2-F1-P2-O3/O3 FPAX-A2-F1-P2-O3 FPW201-V1-A2-F1-P2-O6-± 866W FPWK201-V1-A2-F1-P2-O6-± 866W/± 866Var FPWWH201-V1-A2-F1-P1-O8/X1-866W FPF-F1-P2-O13/B3 FPPF-V1-A2-F1-P2-O8/D1 FPD-1-A1-P2-O3 FPD-2-A1-P2-O3/O3 FPH-I3-P1-X2 FPS-I1-4-P2-O8/ GPA-A2-F1-P2-O3 GPVX-V1-F1-P2-O3 GPW201-V1-A1-F1-P2-O3-± 173.2W GPK201-V1-A2-F1-P2-O6-± 866Var GPWK201-V1-A2-F1-P2-O6-± 866W /± 866Var GPWWH201-V1-A2-F1-P1-O8/X1-866W GPF-F1-P2-O13/B3 GPPF-V1-A2-F1-P2-O8/D1 GPAN201-A2-F1-P2-O3-1A EPA-A2-P2-F1-O3 EPW201-V1-A2-F1-P2-O6-± 866W EPWWH201-V1-A2-F1-P1-O8/X1-G-866W EPF-V1-P2-F1-O3-B3 EPPF-V1-A2-P2 -F1-O8-D1/ EPD-2-S7-P2-O3/O3 EPT-2-T1-Y1-P2-O3.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.