Main functions and Characteristics
Transforms the measured signal to a voltage, after HCNR200 linearity photodiode transforms to DC output which has extremely good linear relations with the measured signal, uses the computer aided designed, the principle is simply, circuitry designed concisely, reliability is highly and installment is conveniently.
Notice
Operating environment should not have the electric dust and gas of corrosive metal and destruction insulation existence, the altitude should less than 2,500 meters.
The Zero and CAL have been adjusted when products left factory. Please don't adjust at will.
Haiyan Jinhan Electronic Technology Co.,Ltd
EP Series Electric Quantity Transducer
EPA |
EPAR |
EPAS |
EPAT |
EPAX |
|
EPV |
EPVR |
EPVS |
EPVT |
EPVX |
|
EPAN |
EPAN201 |
EPAN301 |
EPVN |
EPVN201 |
EPVN301 |
EPW |
EPW201 |
EPW301 |
EPWT |
EPWT201 |
|
EPK |
EPK201 |
EPK301 |
EPKT |
EPKT201 |
|
EPWK |
EPWK201 |
EPWK301 |
EPWA |
EPWA201 |
EPWA301 |
EPKA |
EPKA201 |
EPKA301 |
EPWKA |
EPWKA201 |
EPWKA301 |
EPWH |
EPWH201 |
EPWH301 |
EPKH |
EPKH201 |
EPKH301 |
EPWWH |
EPWWH201 |
EPWWH301 |
EPKKH |
EPKKH201 |
EPKKH301 |
EPF |
EPFT |
EPPF |
EPPFT |
EPD |
EPH |
EPS |
|
|
|
|
|
The model of this series is shown in the following table :
Product |
Model No. |
Swap model |
AC current transducer(1 unit of avg. to rms conversion) |
GPA |
EPA |
AC current transducer(1 unit of avg. to rms conversion) |
GPV |
EPV |
AC current transducer( 2 wires / 4~20mA ( 8~36V DC powered) |
GPA2 |
EPA2 |
AC current transducer( 2 wires / 4~20mA ( 8~36V DC powered) |
GPV2 |
EPV2 |
AC current transducer( 2 wires / 4~20mA ( 8~36V DC powered) |
GPAX2 |
EPAX2 |
AC current transducer( 2 wires / 4~20mA ( 8~36V DC powered) |
GPVX2 |
EPVX2 |
AC current transducer(1 unit of avg. to rms self-powered) |
GPAS |
EPAS |
AC current transducer(1 unit of avg. to rms self-powered) |
GPVS |
EPVS |
AC current transducer(3 unit of avg. to rms self-powered) |
GPAXS |
EPAXS |
AC current transducer(3 unit of avg. to rms self-powered) |
GPVXS |
EPVXS |
AC current transducer(TRMS conversion ) |
GPAR |
EPAR |
AC current transducer(TRMS conversion ) |
GPVR |
EPVR |
AC current transducer(2 output) |
GPAT |
EPAT |
AC current transducer(2 output) |
GPVT |
EPVT |
AC current transducer(3 unit of avg. to rms conversion) |
GPAX |
EPAX |
AC current transducer(3 unit of avg. to rms conversion) |
GPVX |
EPVX |
3 phase 3 wire reactive power transducer |
GPK201 |
EPK201 |
3 phase 3 wire reactive power transducer(2 output) |
GPKT201 |
EPKT201 |
3 phase 3 wire Active power&reactive power transducer |
GPWK201 |
EPWK201 |
3 phase 3 wire Active power transducer |
GPKT201 |
EPKT201 |
3 phase 3 wire Active power transducer(2 output) |
GPWT201 |
EPWT201 |
3 phase 3 wire wate&var¤t transducer |
GPWKA201 |
EPWKA201 |
3 phase 4 wire reactive power transducer |
GPK301 |
EPK301 |
3 phase 4 wire reactive power transducer(2 output) |
GPKT301 |
EPKT301 |
3 phase 4 wire Active power&reactive power transducer |
GPWK301 |
EPWK301 |
3 phase 4 wire Active power transducer |
GPKT301 |
EPKT301 |
3 phase 4 wire Active power transducer(2 output) |
GPWT301 |
EPWT301 |
3 phase 4 wire wate&var¤t transducer |
GPWKA301 |
EPWKA301 |
3 phase 3 wire Active energy transmitter |
GPWH201 |
EPWH201 |
3 phase 3 wire Reactive energy transmitter |
GPKH201 |
EPKH201 |
3 phase 3 wire Active power+energy transducer |
GPWWH201 |
EPWWH201 |
3 phase 3 wire Reactive power+energy transducer |
GPKKH201 |
EPKKH201 |
3 phase 4 wire Active energy transduce |
GPWH301 |
EPWH301 |
3 phase 4 wire Reactive energy transduce |
GPKH301 |
EPKH301 |
3 phase 4 wire Active power+energy transducer |
GPWWH301 |
EPWWH301 |
3 phase 4 wire Reactive power+energy transducer |
GPKKH301 |
EPKKH301 |
Frequency transducer |
GPF |
EPF |
Power factor transducers |
GPPF |
EPPF |
Dc isolation transmitter |
GPD |
EPD |
Dual output dc isolation transmitter |
GPDT |
EPDT |
Power controller |
GPS |
EPS |