• Gpa, Gpax, Gpar High-Reliability Current Transducer
  • Gpa, Gpax, Gpar High-Reliability Current Transducer
  • Gpa, Gpax, Gpar High-Reliability Current Transducer
  • Gpa, Gpax, Gpar High-Reliability Current Transducer
  • Gpa, Gpax, Gpar High-Reliability Current Transducer

Gpa, Gpax, Gpar High-Reliability Current Transducer

Kind: New-Type Transmitter
Type: AC Transmitter
Phase: Single
Wire-Assembly Type: Two-wire Transmitter
Accuracy Grade: 0.5G
Certification: ISO
Samples:
US$ 165/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

Contact Supplier

Diamond Member Since 2023

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
Gpa, GPAX, GPAR, EPA, EPAX, EPAR
Customized
Customized
Manufacturers
Haiyan Jinhan Electronic Technology Co.,Ltd
MOQ
1 Piece
Production Process
Integration
Shell Material
Beige Plastic-Shell
Dimension
34.5*75*113
Installation
35mm DIN Sliding-Way
N.W
About 0.5kg
Freight
by Air
Export Markets
Global
Delivery Time
Depend on Quantity
Transport Package
Independent Carton Package
Specification
SGS
Trademark
Jinhan
Origin
China
HS Code
9030390000
Production Capacity
1000 PCS/Year

Product Description

                            Gpa,GPAX,GPAR High-Reliability Current Transducer
1. Summarize:

Electric quantity transducer is a measuring instrument that it makes measurand electric quantity (AC Current/Voltage Active  Power Reactive Power Active Energy Reactive  Energy Power Line Frequency.Phase Angle Power Factor DC Current/Voltage) turn into DC current or voltage output that accroding to proportional linearity . It widely applied to electric measurement autocontrol and system altitude that in electric power Coal metallurgy railway and so on.

Applied Standards & Rules
       Measuring and conversion IEC 688 / 1992 - 04
       Dielectrical strength IEC 688 2KVac / 1 min.
      Surge and Impulse test ANSI C37.90 / 1989
      IEC 255-3 (1989) 4KV 1.2 x 50 us


      Current transducers convert AC input into load independent DC current & voltage output signal. This signal is highly accurate & proportionally linear to the AC input. GPA versions convert the AC sinusoidal waveforms to linear DC output calibrated to the RMS value.

2.Models:
      GPA         single phase current
      GPAS       single phase self-powered current
      GPA2       2 wires / 4~20mA ( 8~36V DC powered )
      GPAX       three phase current
      GPAXS    three phase self-powered current
      GPAX2    2 wires / 4~20mA ( 8~36V DC powered )
      GPAR      single phase TRMS current

The following models can be used with each other:
      EPA         single phase current
      EPAS       single phase self-powered current
      EPA2       2 wires / 4~20mA ( 8~36V DC powered )
      EPAX       three phase current
      EPAXS    three phase self-powered current
      EPAX2    2 wires / 4~20mA ( 8~36V DC powered )
      EPAR      single phase TRMS current


3.Technical Specifications:
Gpa, Gpax, Gpar High-Reliability Current Transducer

3.Models&Specifications
Gpa, Gpax, Gpar High-Reliability Current Transducer

4.Terminal Connection
Gpa, Gpax, Gpar High-Reliability Current Transducer


5.Dimensional Drawings
Gpa, Gpax, Gpar High-Reliability Current Transducer





Technical Specification   
 
Reference Standard    
 
GB/T 13850-1998(IEC688-1992) 
 
Accuracy  
Long Term stability  ≤±0.5%/year.No accumulation error
Temperature influence ≤ 100ppm/oC
Response Time
 
  <400ms
 
Output Ripple <1.0%(peak-peak value)
 
Input burden Current less 0.2VA;voltage less 0.1VA
 
 Frequency  Nominal frequency ±10%
 
Maximum output load Current output Max10V pressure drop
 
 Auxiliary power  Ratedvoltage80%-120%,rated current 90%-110% 
Auxiliary load effect 
 
 <± 0.2% 
 
Allow excessive input  Current 2rate continuous 10rate 20 secs voltageMax 2ratecontinuous 
 
Dielectric strength Input /output /power/between the crust 2KV AC 1 minIEC866 
 
Impact test ANSIC37.90a/1973,IEC255-4 (5kV1.2/50us PulsedVoltage) 
Calibration amplitude Full scale least±3%,zero least±1%
 
Magnetic field effect 0.4KA/m magnetic field strength change <0.05%
 
Operating condition  Temperature -10~55oC relative humidity≤95%RHnoncondensing 
Storage condition  Temperature -40~70oC relative humidity ≤95% RHnoncondensing 
 
Haiyan Jinhan Electronic Technology CO.,LTD

The model of this series is shown in the following table :
Product Model No. Swap model
AC current transducer(1 unit of avg. to rms conversion) GPA EPA
AC current transducer(1 unit of avg. to rms conversion) GPV EPV
AC current transducer( 2 wires / 4~20mA ( 8~36V DC powered) GPA2 EPA2
AC current transducer( 2 wires / 4~20mA ( 8~36V DC powered) GPV2 EPV2
AC current transducer( 2 wires / 4~20mA ( 8~36V DC powered) GPAX2 EPAX2
AC current transducer( 2 wires / 4~20mA ( 8~36V DC powered) GPVX2 EPVX2
AC current transducer(1 unit of avg. to rms self-powered) GPAS EPAS
AC current transducer(1 unit of avg. to rms self-powered) GPVS EPVS
AC current transducer(3 unit of avg. to rms self-powered) GPAXS EPAXS
AC current transducer(3 unit of avg. to rms self-powered) GPVXS EPVXS
AC current transducer(TRMS conversion ) GPAR EPAR
AC current transducer(TRMS conversion ) GPVR EPVR
AC current transducer(2 output) GPAT EPAT
AC current transducer(2 output) GPVT EPVT
AC current transducer(3 unit of avg. to rms conversion) GPAX EPAX
AC current transducer(3 unit of avg. to rms conversion) GPVX EPVX
3 phase 3 wire reactive power transducer GPK201 EPK201
3 phase 3 wire reactive power transducer(2 output) GPKT201 EPKT201
3 phase 3 wire Active power&reactive power transducer GPWK201 EPWK201
3 phase 3 wire Active power transducer GPKT201 EPKT201
3 phase 3 wire Active power transducer(2 output) GPWT201 EPWT201
3 phase 3 wire wate&var&current transducer GPWKA201 EPWKA201
3 phase 4 wire reactive power transducer GPK301 EPK301
3 phase 4 wire reactive power transducer(2 output) GPKT301 EPKT301
3 phase 4 wire Active power&reactive power transducer GPWK301 EPWK301
3 phase 4 wire Active power transducer GPKT301 EPKT301
3 phase 4 wire Active power transducer(2 output) GPWT301 EPWT301
3 phase 4 wire wate&var&current transducer GPWKA301 EPWKA301
3 phase 3 wire Active energy transmitter GPWH201 EPWH201
3 phase 3 wire Reactive energy transmitter GPKH201 EPKH201
3 phase 3 wire Active power+energy transducer GPWWH201 EPWWH201
3 phase 3 wire Reactive power+energy transducer GPKKH201 EPKKH201
3 phase 4 wire Active energy transduce GPWH301 EPWH301
3 phase 4 wire Reactive energy transduce GPKH301 EPKH301
3 phase 4 wire  Active power+energy transducer GPWWH301 EPWWH301
3 phase 4 wire  Reactive power+energy transducer GPKKH301 EPKKH301
Frequency transducer GPF EPF
Power factor transducers GPPF EPPF
Dc isolation transmitter GPD EPD
Dual output dc isolation transmitter GPDT EPDT
Power controller GPS EPS
 

Share This Story, Choose Your Platform!
 

Send your message to this supplier

*From:
*To:
avatar Mr. Zengyong
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now