Fpa, Fpax, Fpar, AC Current Transducers

Product Details
Customization: Available
Kind: New-Type Transmitter
Type: AC Transmitter
Manufacturer/Factory & Trading Company
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
5
Year of Establishment
2022-03-25
  • Fpa, Fpax, Fpar, AC Current Transducers
  • Fpa, Fpax, Fpar, AC Current Transducers
  • Fpa, Fpax, Fpar, AC Current Transducers
  • Fpa, Fpax, Fpar, AC Current Transducers
  • Fpa, Fpax, Fpar, AC Current Transducers
  • Fpa, Fpax, Fpar, AC Current Transducers
Find Similar Products
  • Overview
  • Applied Standards&Rules
  • Models
  • Order form
  • Input &Output parameters
  • Specification
Overview

Basic Info.

Model NO.
FPA, FPAX, FPAR
Phase
Single
Wire-Assembly Type
Two-wire Transmitter
Accuracy Grade
0.2G
Certification
ISO
Customized
Customized
Manufacturers
Haiyan Jinhan Electronic Technology Co., Ltd
MOQ
1 Piece
Production Process
Integration
Shell Material
Iron-Shell
Dimension
75*50*113(Mm)
Installation
Screws
N.W
About 0.5kg
Freight
by Air
Export Markets
Global
Delivery Time
Depend on Quantity
Transport Package
Independent Carton Package
Specification
SGS
Trademark
Jinhan
Origin
China
HS Code
9030390000
Production Capacity
1000 PCS/Year

Product Description

Applied Standards&Rules

     Measuring and conversion IEC 688 / 1992 - 04
     Dielectrical strength IEC 688 2KVac / 1 min.
     Surge and Impulse test ANSI C37.90 / 1989
     IEC 255-3 (1989) 4KV 1.2 x 50 us
 
Models

       FPA     1 unit of avg. to rms conversion
       FPAX   3 unit of avg. to rms conversion
       FPAR   Ture rms conversion
 
Order form

Fpa, Fpax, Fpar, AC Current Transducers


 
Input &Output parameters

Fpa, Fpax, Fpar, AC Current Transducers
Py : DC24 / 48 / 125 V ± 20% or other range under specified

Note:
External power mode suitably for all output types
Internal power mode, only suitably for 0-1mA / 0-20mA / 0-1V / 0-5V / 0-10V output

 
Specification

Accuracy ( 23±3°C )                0.2% RO .......... FPA, FPAX, FPV, FPVX                                                        
                                             0.2% RO .......... FPAR, FPVR                                    
Maximum output load              DC current mode : maximum 10V drop                                                        
                                             DC voltage mode : maximum 5mA drive                                                        
Dielectric strength                  AC 2KV 1 minute between terminals; AC 2.6KV 1 minute / terminals to case
Surge and impulse test           ANSI C37.90 / 1989, IEC 255-3 (1989) 4 KV 1.2 x 50 us
Maximum input over              Current related input                                                  Voltage related input
                                                    1A / 5A                                10A                                                             
                                            4 x rated / continuous       2 x rated / continuous              1.5 x rated / continuous
                                           10 x rated / 10 seconds     25 x rated / 1 second               2 x rated / 10 seconds
                                            50 x rated / 1 second        50 x rated / 0.5 second            
                                            80 x rated / 0.5 second                                                                   
Input burden                        Current less 0.2 VA; voltage less 0.1 VA                                                        
Response time & ripple        Ø400 ms for step change 0-99%               ripple less 0.5% ro peak to peak
Frequency                            45 ~ 400 Hz                                                                 
Stability                              Temperature range ( 20 to 30°C )                        long term stability / year
                                          Maximum 60 ppm / °C        less 0.2% draft / year typically
Storage condition              Temperature range -25 to 70°C, RH 20 to 95% non condensed
Operating condition          Temperature range -20 to 65°C, RH 0 to 99% non condensed
Magnetic field effect          < 0.01% under 100 ampere turns at 1M center                    
Power dissipation            Maximum 3.5 VA for FPA / FPAR / FPV / FPVR; 8 VA for FPAX / FPVX

6.Terminal Connection
Fpa, Fpax, Fpar, AC Current Transducers

Model and Ordering
 FPA-An-Fn-Pn-On

Example:
 
1. FPA-A2-F1-P2-03

Input:5A
Auxiliary Frequency:50Hz
Power:AC 220V
Output:4-20mA

If you have any questions about this,welcome to contact us.
We are all at service.
Fpa, Fpax, Fpar, AC Current Transducers

 
 


Technical Specification   
Reference Standard    
 
GB/T 13850-1998(IEC688-1992) 
 
Accuracy  
Long Term stability  ≤±0.2%/year.No accumulation error
Temperature influence ≤ 100ppm/oC
Response Time
 
  <400ms
 
Output Ripple <0.4%(peak-peak value)
 
Input burden Current less 0.2VA;voltage less 0.1VA
 
 Frequency  Nominal frequency ±10%
 
Maximum output load Current output Max10V pressure drop
 
 Auxiliary power  Ratedvoltage80%-120%,rated current 90%-110% 
Auxiliary load effect 
 
 <± 0.1% 
 
Allow excessive input  Current 3rate continuous 10rate 30 secs voltageMax 2ratecontinuous 
 
Dielectric strength Input /output /power/between the crust 2KV AC 1 minIEC866 
 
Impact test ANSIC37.90a/1973,IEC255-4 (5kV1.2/50us PulsedVoltage) 
Calibration amplitude Full scale least±3%,zero least±1%
 
Magnetic field effect 0.4KA/m magnetic field strength change <0.05%
 
Operating condition  Temperature -10~55oC relative humidity≤95%RHnoncondensing 
Storage condition  Temperature -40~70oC relative humidity ≤95% RHnoncondensing 
 


Haiyan Jinhan Electronic Technology CO.,LTD
FP Series Electric Quantity Transmitter
FPA FPAR FPAT FPAX    
FPV FPVR FPVT FPVX    
FPW FPW201 FPW301 FPWT FPWT201  
FPK FPK201 FPK301 FPKT FPKT201  
FPWK FPWK201 FPWK301 FPWKA FPWKA201 FPWKA301
FPWH FPWH201 FPWH301 FPKH FPKH201 FPKH301
FPWWH FPWWH201 FPWWH301 FPKKH FPKKH201 FPKKH301
FPF FPFT FPPF FPPFT FPH FPS
FPD-1 FPD-2 FPDH-1 FPDH-2 FPT-1 FPT-2

We can provide the product model and specifications:
 
Product Model No.
AC current transducer JD194-BS4I-N
AC voltage transducer JD194-BS4U-N
AC current transducer JD194-BS4I
DC current transducer JD194-BS5I
AC voltage transducer JD194-BS4U
DC voltage transducer JD194-BS5U
Power transmitter JD194-BS4P
Power transmitter JD194-BS4Q
Power factor transducer JD194-BS4H7
Frequency transmitter JD194-BS4F7
Integrated transmitter JD194-BS4Z6
Integrated transmitter JD194-BS4Z8
Integrated transmitter JD194-BS4Z-S
Temperature transmitter BS6T
Resistance transducer BS6R
Intelligent signal conditioner BS6M
AC current transducer RPA
AC voltage transducer RPV
AC current transducer RPAT
AC voltage transducer RPVT
AC current transducer RPAX
AC voltage transducer RPVX
Power transmitter RPW
Power transmitter RPK
Power transmitter RPWK
Power factor transducer RPPF
Frequency transmitter RPF
Frequency transmitter RPFT
AC current transducer CPA
AC voltage transducer CPV
AC current transducer CPAT
AC voltage transducer CPVT
AC current transducer CPAX
AC voltage transducer CPVX
Power transmitter CPW
Power transmitter CPK
Power transmitter CPWK
Power factor transducer CPPF
Frequency transmitter CPF
Frequency transmitter CPFT
Power transmitter FPW
Power transmitter FPK
Power transmitter FPWT
Power transmitter FPKT
Power transmitter FPWK
DC transducer FPD-1H
DC transducer FPD-2H
DC transducer FPDH-1H
DC transducer FPDH-2H
AC current transducer FPA
AC voltage transducer FPV
AC current transducer FPA2
AC voltage transducer FPV2
AC current transducer FPAR
AC voltage transducer FPVR
AC current transducer FPAT
AC voltage transducer FPVT
AC current transducer FPAX
AC voltage transducer FPVX
AC current transducer FPAX2
AC voltage transducer FPVX2
AC current transducer GPA
AC voltage transducer GPV
AC current transducer GPA2
AC voltage transducer GPV2
AC current transducer EPA
AC voltage transducer EPV
AC current transducer GPAT
AC voltage transducer GPVT
AC current transducer GPAX
AC voltage transducer GPVX
AC current transducer GPAX2
AC voltage transducer GPVX2
AC current transducer GPAS
AC voltage transducer GPVS
Generator negative sequence current meter FPFX-100
Temperature transmitter FT3
Temperature transmitter FT2
Temperature transmitter FT2-C
Temperature transmitter GPT
Temperature transmitter EPT
Shift transmitter FPB

Share This Story, Choose Your Platform!

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier