Juxta Power Factor Transducers

Kind: Two-wire Transmitter
Type: AC Transmitter
Phase: Three
Wire-Assembly Type: Four-wire Transmitter
Accuracy Grade: 0.2G
Certification: ISO
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Customized
Customized
Trademark
jinhan
Origin
China
HS Code
9030339000
Production Capacity
5000

Product Description

JUXTA COMBINATION WATT/VAR TRANSDUCERS
1.GENERAL
The 2469 and 2489 Power Factor transducers have an analog output corresponding to 1- Cosine of the phase angle of the input current relative to the input voltage signal. The analog output will indicate lead- ing or lagging Power Factor by its direction from center which would be either 0 mA or 12mA based on output selection.


2.SPECIFICATIONS:
Model #   2469 2489
Current input / range 0-1 Amp AC or 0-5 Amp AC
10 to 200% of rated input
Current input over range capability 200% of rated input continuous
1000% of rated input for 5 seconds
Current input burden < 0.2VA per element
Voltage inputs and range: Input powered range
Auxiliary powered range
Voltage input burden per element
120V 240V
100-135VAC 200-264VAC
0-120% rated input
< 0.5VA < 1.0VA
120V 240V
85-135VAC 170-264VAC
0-120% of rated input
< 0.5VA < 1.0VA
Sustained Voltage input overange 150% of rated input without damage (Auxiliary powered only)
  ±1mADC into a 10kW max. load; 10VDC output compliance
4-12-20 mADC into a 750W max. load; 15VDC output compliance
Rated outputs ±0.01 Power Factor
Accuracy 0-1-0 Power Factor or 0.5-1-0.5 Power Factor
Output calibration / element Zero: ± 1% minimum
Span: ± 2% minimum
Zero: ± 5% minimum
Span: ± 10% minimum
External calibration adjustment < 400 milliseconds (0-99% of output)
Response time 0.3% of FS peak-to-peak max. 0.5% of FS peak-to-peak max.
Output ripple 2500 VAC input to output, power and case
2000 VAC aux. power to output and case 500 VAC output to case
Isolation IEEE472/ANSI C37.90.1 - 1989, JIS C1111 (5KV 1.2 x 50 microseconds)
Surge Withstand Capability > 10 megohm / 500VDC input/output/power/case
Insulation resistance -20°C to +60°C
Operating temperature 0 - 90% relative humidity (non-condensing)
Operating humidity ±500 PPM / °C of span ±150 PPM / °C of span
Temperature effect < 0.2% at 400 AT/m
External magnetic field <1% of span Aux. Pwr.±0.01 max.±20% rated V.
Self pwr.±0.01 max. in range of Aux. Pwr
Influence  :  unbalanced  currents  /
phase  interaction  / Power Factor
<2% of span <0.02 PF for 20-200% rated input current
Weight <4% of rated current 4% of rated input
Shock 1000g (2.2 lbs.)
Vibration <0.2% after 50G, 3 Axis and 6 repetitions
UL Recognition <0.2% after 16.7 Hz, 4 mmp-p 1 hour, 3 Axis
     


3) STANDARD MODELS:
120 VAC, 5AAC, 60 Hz, input powered 2469 2489
PF- Single phase / ±1mA  output
PF- Single phase / 12±8mA output
PF- 3P3W  balanced  /  ±1mA  output
PF- 3P3W balanced / 12±8mA output
PF- 3P4W  balanced  /  ±1mA  output
PF- 3P4W balanced / 12±8mA output
246971-540-AFB-0-P 248971-540-AFB-0-P
246971-540-AHF-0-P 248971-540-AHF-0-P
246973-540-AFB-0-P 248973-540-AFB-0-P
246973-540-AHF-0-P 248973-540-AHF-0-P
246974-540-AFB-0-P 248974-540-AFB-0-P
246974-540-AHF-0-P 248974-540-AHF-0-P

NOTE: See order format on next page for additional ratings, frequency calibrations, power-up and output options.
Auxiliary power supply options <5.0 VA burden. 14