Product Description
roduct introduction
Visually reflect the combustion status of the boiler and guide the operator to optimize the combustion.
Performance characteristics
Integrated structure / in situ measurement
The measuring unit is an integrated structure of fly ash sampling and measurement, and no ash sample is taken, and the detection is completed in the ash hopper.
Using a unique spectrum analysis technique, the carbon content of fly ash is analyzed based on the spectral characteristics of unburned carbon in fly ash.
technical parameter
*Measuring range: 0%~10%
*Measurement accuracy: ±0.5%C
*Working temperature: 50~150°C
*Output signal: 4~20mA
*Power supply voltage: 220V
*Detection time: 0.5~5min (different load differences)
*Air source pressure: 0.4~0.7MPa
*Measurement period: connected to the anode rapping signal, synchronous measurement of falling ash